技術文(wen)章(zhang)
Article公司(si)產品系(xi)列(lie)
Product range咨(zi)詢(xun)熱線(xian):
13701917799
更新更新時間:2022-09-20
瀏(liu)覽量:1144
壓力(li)表測(ce)量範圍(wei)的確定(ding)
為(wei)了(le)保(bao)證彈(dan)性(xing)元(yuan)件(jian)能(neng)在彈(dan)性(xing)變(bian)形的安全(quan)範圍(wei)內可(ke)靠(kao)地工(gong)作,在選擇壓(ya)力表(biao)量(liang)程(cheng)時,必須根(gen)據(ju)被測(ce)壓力(li)的大小(xiao)和(he)壓(ya)力變(bian)化(hua)的快(kuai)慢(man),留有(you)足(zu)夠(gou)的余(yu)地,因(yin)此(ci),壓(ya)力表的(de)上(shang)限(xian)值應該高於(yu)工(gong)藝生產(chan)中(zhong)可能(neng)的(de)zui大(da)壓力值。根(gen)據(ju)“化工(gong)自(zi)控(kong)設計(ji)技術規定”,在測量(liang)穩(wen)定壓力時,zui大(da)工(gong)作壓力(li)不應超(chao)過測量上(shang)限(xian)值的2/3;測量脈動壓力時,zui大(da)工(gong)作壓力(li)不應超(chao)過測量上(shang)限(xian)值的1/2;測量高壓(ya)時,zui大工(gong)作壓力(li)不應超(chao)過測量上(shang)限(xian)值的3/5。壹般被測(ce)壓力(li)的zui小(xiao)值應不低於(yu)儀表(biao)測量(liang)上(shang)限(xian)值的1/3。從而保(bao)證儀表(biao)的輸(shu)出量與輸(shu)人量之間的(de)線(xian)性(xing)關系(xi)
根(gen)據(ju)被測(ce)參數(shu)的zui大值和(he)zui小(xiao)值計算出儀表(biao)的上(shang)、下(xia)限(xian)後(hou)、不能以(yi)此(ci)數(shu)值直(zhi)接(jie)作為(wei)儀表(biao)的測(ce)量範圍(wei)。我們(men)在選用(yong)儀表(biao)的標(biao)尺(chi)上(shang)限(xian)值時,應在國家規定的(de)標(biao)準系(xi)列(lie)中(zhong)選取(qu)。中(zhong)國的(de)壓(ya)力(li)表測量(liang)範圍(wei)標準系(xi)列(lie)有(you):-0.1-0.06,0.15;0-1,1.6,2.5,4,6,10X10" MPa(其中(zhong)n為(wei)自(zi)然(ran)整數.可(ke)為(wei)正(zheng)、負值)